Warning: "continue" targeting switch is equivalent to "break". Did you mean to use "continue 2"? in /home/akesis/public_html/wp-content/plugins/jupiter-donut/includes/helpers/minify/src/Minifier.php on line 227 Gemini360RT - Innovating radiation medicine

Akesis Gemini360RT® Platform

Innovating radiation medicine

U.S. FDA 510(k) cleared

Akesis Gemini360RT® Platform

.

.

The Akesis Gemini360RT* is a LINAC-based radiotherapy platform, optionally equipped with a secondary Gamma head to expand treatment capabilities. The LINAC system features a high-throughput FFF 6 MV beam, 120-leaf MLC, a 40 x 40 cm maximum field size, and a dose rate of up to 1400 MU/min, supporting the full range of modern radiotherapy techniques including 3DCRT, IMRT, VMAT, SRS/FSRT, SBRT/SABR, and Online Adaptive RT. The optional Gamma head, based on the same patented rotating gamma technology as the Akesis Galaxy RTi, adds non-coplanor, high-precision intracranial and extracranial SRS, SRT, and SBRT/SABR capabilities enabling more nuanced dose painting and steep dose fall-off.

Broad range of advanced radiotherapy treatments

LINAC-based treatment options

  • Continuous 360-degree rotational platform
  • 6MV FFF LINAC with max. dose rate = 1400 cGy/min
  • 40cm x 40cm max. field size
  • 120 leaf MLC
  • TPS, OIS (with R&V) included (optional)
  • In-line CBCT & kV/kV Imaging
  • Intrafractional Skull & Fiducial tracking with optional couch corrections
  • Fully automated daily machine QA
  • ~8-minute (VMAT) treatment times
  • Treatment options include:
    • IMRT (VMAT + Step and Shoot)
    • 3DCRT
    • Breast tangents
    • SRS/FSRT
    • SBRT/SABR
    • On-line Adaptive RT
    • Palliative treatments

Gamma head provides nuanced dose painting abilities paired with steep dose fall off

  • High-precision intracranial and extracranial SRS, FSRT, and SBRT/SABR
  • True non-coplanar beam delivery without couch repositioning

Multiple in-line, real-time imaging options

  • In-line CBCT & kV/kV Imaging
  • Intrafractional Skull & Fiducial tracking with optional couch corrections

Flexible Treatment Planning

  • Akesis all-in-one TPS included
    • 3DCRT, IMRT, VMAT, SRS, SBRT, etc.
    • LINAC + Gamma head planning
    • Third-party system (RayStation, Eclipse) support available
  • Online and offline Adaptive RT (ART) planning
  • Dose calculation and AI tools:
    • Fast Photon, Collapsed Cone (CCCS), and GPU-accelerated Monte Carlo
    • AI-based auto-contouring
    • Multi-modality image fusion: CT, MR, and PET

Clinical Value

  • Simultaneous multi-target irradiation

  • Local dose painting

  • Grid/lattice irradiation

*U.S. FDA 510(k) cleared

Resources

Product information